Ultrasonic Flowmeter FD-7000




Up to now, Doppler ultrasonic flow meters have required significant quantities of suspended particles or gas bubbles to reflect sound signals. Now, with the Model FD-7000 Ultrasonic Flowmeter, this is no longer required. When the FD-7000 is used to measure the flow of liquids containing suspended solids or bubbles, the transducers are mounted on a straight run of pipe in the same manner as other ultrasonic meters.

In applications where insufficient “reflectors” exist (a condition indicated by a low reading on the FD-7000’s Flow Analyzer bar graph), the transducers are relocated to a point in the piping where non-symmetrical hydraulic turbulence will be present – ideally just downstream of a 90-degree elbow. The FD-7000’s unique digital filtering system and signal recognition circuitry transforms the reflections from this non-symmetrical, and not necessarily linear, turbulence into a useable and linear data format.


A backlit, 2 line by 20 character, alphanumeric LCD offers simultaneous flowrate and totalizer displays. The FD-7000 is designed for ease of use in the field. Only a few simple keypad entries are required to configure the flowmeter for any given pipe and flow measurement application. The encapsulated, submersible design of the transducer sensor head allows it to be easily mounted to the pipe surface with the coupling compound and elastic bands that are supplied with the unit.

A 20 ft. (6 meter) retractable cable for connection to the transmitter/indicator unit is supplied as as integral part of the sensor. The FD-7000 sensor is utilized on pipes that range in internal diameter from 25 to 3048 mm (1 to 120"). Flowrates can be measured in smaller pipes from 6 to 25 mm ( 1 /4 to 1") in diameter with use of the small pipe sensor, model FD-7000-S1. These units are not to be used for distilled water or ultra clean water applications.

Ultrasonic Flowmeter FD-7000 is made in USA and advertised at www.omega.com.


SPECIFICATIONS
System Accuracy:
±2% of F.S.

Velocity Range:
0.15 to 6.2 meters/second (0.5 to 20 feet/second)

Measuring Units:
FPS, GPM, MGD

Linearity:
±0.2% of F.S.

Repeatability:
0.4% of F.S.

Flow Rate Display:
6-digit LCD

Totalizer Display:
6-digit LCD (resettable)

Outputs:
4 to 20 mA into 600 Ohms max., isolated

Power Requirements:
115 Vac ±10%, 50/60 Hz, 20 VA max. (standard); 230 Vac 50/60 Hz (optional). Internal gel cell battery provides 8 hrs. of continuous operation

Liquid Requirements:
Full-pipe, low-viscosity (water-like) liquid

Transmitter/Indicator Operating
Temperature:
-30 to 70°C (-22 to 158°F)

Sensor Operating Temperature:
-40 to 121°C (-40 to 250°F)

Dimensions:
432 L x 279 W x 203 mm H
(17 x 11 x 8")

Weight:
10 kg (22 lb)

Enclosure:
NEMA-4X (IP65)


Read more...

Portable Doppler: Ultrasonic Flowmeter, FD613




The FD610 Series ultrasonic flow meter is made in USA and advertised at www.omega.com. It has features advanced Trans-Phase measuring technology, providing accurate and reliable flow velocity assessments in closed piping systems. The FD610 Series utilizes a non-invasive clamp-on transducer which is placed on the outside of a pipe. Within seconds, the large 18 mm (0.7") LCD provides stable flow rate readings in feet per second or meters per second. This product operates on metal or plastic pipes containing liquids with more than 100 ppm of 100 micron or larger suspended solids or entrained gases.


PRINCIPLE OF OPERATION
The FD610 Series flow meter utilizes an advanced Trans-Phase measuring technique, providing accurate, non-invasive fluid velocity assessment without opening the pipe. The FD610 Series utilizes two piezoelectric crystals contained within one transducer to transmit ultrasonic energy into the fluid stream and receive back energy reflected off discontinuities (suspended particles or entrained gases) within the moving liquid. Transformations that result from the energy reflections are processed and converted to a measurement of fluid velocity by the sophisticated software algorithm. The processor also controls all operations of the instrument from its ultra-efficient battery management circuitry to a proprietary FIR (Finite Impulse Response) filtration program.

SPECIFICATIONS
Supply Voltage:
Battery powered, non-rechargeable alkaline, four AA cells, providing over 30 hours of continuous operation

Flow Range:
0.30 to 30.00 FPS (0.10 to 9.00 MPS)

Display:
Single line – four-digit LCD readout of velocity (18 mm (0.7") digits), signal strength, measuring units, and low battery indication

Temperature:
-20 to 60°C (-28 to 140°F)

Enclosure Rating/Dimensions:
NEMA-12X ABS plastic; 200 H x 100 W x 38 mm H (7.76 x 4 x 1.5")

Weight: 0.7 kg (1.5 lb)

Accuracy: ±2% full scale

Transducer
Transducer Material:
Plated body; ULTEM 1000 sensor material

Cable: 2 m (6.6 ft) cable and connector

Temperature: -40 to 82°C (-40 to 180°F)

Humidity: 0 to 95% non-condensing
Mounting Method:
Clamp-on style with DOW 111 coupling compound


Read more...

Fetal Monitoring Transducers from Hewlett Packard

They are advertised by Sun Coast Medica that offering brand new Corometrics® and Hewlett Packard® compatible Tocotransducers and Ultrasound Transducers at a fraction of the original manufacturer's cost!

Keep Mom and Baby working together with our Ultrasound Transducer and relax Mom while measuring Baby's heartbeat during labor. The "Leg Plate" and fetal scalp electrodes are used when it is otherwise difficult to hear the heartbeat with the external Ultrasound Transducer. Volume discounts are available upon request.


  • Corometrics® Tocotransducer Model 2260
  • Corometrics® Ultrasound Transducer Models B5600, 5700
  • Hewlett Packard® Tocotransducer Model M1355A
  • Hewlett Packard® Ultrasound Transducer Model M1356A
  • Hewlett Packard® Ultrasound Transducer Model 15245A
  • Brand New
  • One-Year Warranty!


Read more...